VMRD SAA Reader
Is the registration number of your country not listed? Then this product falls within the cascade control system.
*Get 50% discount on VMRD reader when you purchase 3 (15 pack). Choice of VMRD Foal IgG Test or SAA Test. Combination of both products is possible. The discount (150 euro) is automatically calculated when 3 of these products and the VMRD reader are added to the shopping cart. When purchasing 6 boxes of tests and 2 VMRD readers or more, please contact our customer service.
VMRD - Serum Amyloid A Reader
Reader for use with the Serum Amyloid A (SAA) Test and Foal IgG Tests.
Early identification of infection or systemic inflammation is challenging, and initial clinical signs are often subtle.
Serum Amyloid A (SAA) is a valuable tool as it is rapidly responsive to clinical changes. Virtually undetectable in normal horses, it increases within 6-12 hours in acute inflammation and peaks at 1000-fold baseline values – far quicker and more dramatic than fibrinogen or WBC count. As inflammation improves, it begins dropping within 12-24 hours.This dynamic nature of SAA makes it an ideal marker for evaluating disease severity and monitoring progression or resolution of illness, including response to treatment.
10-minute SAA test
Can be used with fresh blood, EDTA blood, or heparin blood
Samples are collected directly from syringe or from blood tube (test within 12 hours of collection)
Objective interpretation quantification of results with VMRD Reader
Results range from 20 μg/mL (normal) up to 3000 μg/mL
Calibration card keeps results consistent and accurate between readers and over time
VMRD SAA UPDATE
Starting with the newest lot of VMRD SAA (Lot # P210815-001) you will now get a specific numerical result for any samples with elevated SAA* - even if it's greater than 3000 μg/mL! You can take advantage of this enhanced upper range and improve your patient monitoring using the existing VMRD Reader. When you receive your order for the newest lot, just make sure to attach the calibration card from the new test box to the side of your reader. The lot-specific calibration system will provide the reader with the right information – no additional equipment required!
*Greatest accuracy is obtained using samples with SAA concentrations up to 3000 ug/mL. Although potentially less precise, a specific and clinically relevant numerical result will be reported for any samples exceeding this SAA value.
Veterinary advice
For use ONLY with cartridges that will be run outside of reader using independent timers.
In this manner, multiple tests can be run simultaneously and read using the same reader.
It is recommended to wait about 30-60 seconds between starting each test to allow enough time to read at completion.
Always change calibration card when using a new box of tests